Tel Number
180-3717-8440
Model:KKJ-MV1400 Series
Description:
KJ-MV Series vacuum molybdenum furnace comprises a high-temperature furnace, a vacuum pump system and a precise pressure gauge. Compared with alumina fiber lining, heating chamber with molybdenum will provide a space with no dust at all.
Brief Introduction:
KJ-MV Series vacuum molybdenum furnace is widely used in heat treatment of metal and special material in vacuum or controlled inert gas atmosphere condition.
Parameters:
Model | KJ-MV1400 | |
Working Temperature | 1200℃ | |
Heating Rate | 0-20 | |
Heating Element | Molybdenum strip | |
Temperature sensor | S-type thermocouple | |
Insulation Material | Molybdenum plate | |
Temperature Accuracy | ±1℃ | |
Power Supply | 110-415V,50/60Hz | |
Vacuum degree | 6.67x10Pa/6.67x10-3Pa | |
Outside tank | Cooled by fans / water | |
Size | ||
Heating Chamber Size mm |
Capacity L |
|
150*150*150 | 3.4 | |
150*150*200 | 4.5 | |
200*200*200 | 8 | |
200*200*300 | 12 | |
300*300*300 | 27 | |
Customization is available! | ||
Optional | Crucible, Touchscreen, Software | |
Notes: | 1, In order to ensure the longest possible service life of furnace parts, we recommend heating rate no higher than 10deg.C/min. 2, Cooling rate no higher than 5deg.C/min. 3, Toxic or explosive gas is not allowed. 4, It is normal that there will be tiny cracks on the wall of the heating chamber, they won’t affect the performance of the furnace, and can be repaired with alumina coating. |
|
Warranty |
One year warranty with life-time technical support. Special notes: 1, Consumables like heating element, quartz, crucible and so on are uncovered. 2, Man-made damage and damage caused by misuse are uncovered. |